Jenkins Electric Logo clear.gif (43 bytes) hdspacer.gif (874 bytes) Grid Resistors
clear.gif (43 bytes)clear.gif (43 bytes)Home Up Feedback Contents Search PDF Catalogs
clear.gif (807 bytes)

Post Glover
Stainless Steel Grid Resistors

Click here for Enclosures for Grid Resistance Banks

Catalog
Number
Type Ampere Resistance
in Ohms
Number
of Taps
List
Price
Rating Total Per Tap
G116R T2 9 41.6 2.60 17 CALL
G0115 T2 11 28.0 3.11 11 CALL
G0114 T2 13 20.0 1.54 15 CALL
G0113 T2 16 15.6 1.20 15 CALL
G0112R T2 20 12.00 1.20 11 CALL
G111R T2 25 10.0 1.00 11 CALL
G0111 T2 27 7.83 0.824 11 CALL
G110 T2 30 5.35 0.618 10 CALL
G19 T2 37 4.00 0.308 15 CALL
G019 T2 41 3.22 0.248 15 CALL
G18 T2 46 2.60 0.200 15 CALL
G018 T2 50 2.20 0.200 13 CALL
G17 T2 57 1.67 0.152 13 CALL
G017 T2 63 1.37 0.152 11 CALL
G16R T2 70 1.12 0.124 11 CALL
G16 T2 75 1.00 0.111 11 CALL
G016 T2 80 0.900 0.100 11 CALL
G15 T2 85 0.756 0.084 11 CALL
G015H T2 91 0.630 0.042 15 CALL
G14H H3 100 0.504 0.056 10 CALL
G014H H3 110 0.430 0.048 10 CALL
G13H H3 120 0.37 0.041 10 CALL
G60R H3 135 0.324 0.036 10 CALL
G58R H3 150 0.250 0.031 9 CALL
G55R H3 165 0.190 0.027 8 CALL
G52R H3 185 0.137 0.023 7 CALL
HC180 HC 180 0.174 0.022 8 CALL
HC225 HC 225 0.144 0.018 8 CALL
HC260 HC 260 0.115 0.0144 8 CALL
HC300 HC 300 0.100 0.0125 8 CALL
HC350 HC 350 0.074 0.0093 8 CALL
HC400 HC 400 0.06 0.0086 7 CALL
HC450 HC 450 0.049 0.0070 7 CALL
HC525 HC 525 0.035 0.0050 7 CALL
clear.gif (43 bytes)
(Click on photo to see the enlarged view)
Type T2 & H3 Bank Dimensions Type H3 Grid Bank

Type HC Grid Bank

Type HC Bank Dimensions
Type T2 & H3 Bank Type H3 Grid Bank Type HC Grid Bank Type H3 Bank

Enclosures for Grid Resistance Banks

Cat.
No.
No. of
Banks
Length Depth Height List Price
(Dimensions in Inches) Screen Louver

Rack with
Screened Cover
for Indoor DutyRack with Screened Cover for Indoor Duty
(Click on photo to see
the enlarged view)

  Four Bank Rack Dimensions

Four Bank Rack Dimensions

Four Bank Rack

EN18-1 1 29 18 13 CALL CALL
EN18-2 2 --- --- 22 CALL CALL
EN18-3 3 Add -S to Catalog Number
to Obtain Screened
Enclosure.
31 CALL CALL
EN18-4 4 40 CALL CALL
EN18-5 5 49 CALL CALL
EN18-6 6 --- 58 CALL CALL
EN18-7 7 Add -O to Catalog Number
to Obtain Louvered
Enclosure for Outdoor Duty.
67 CALL CALL
EN18-8 8 76 CALL CALL
EN18-9 9 85 CALL CALL

NOTES:  To order wound rotor grids, specify:

Motor horsepower or kw rating
Secondary (Rotor) Voltage
Starting Torque as Percent of Full Load (125% Typical)
Secondary Rated Current, Amperes
Number of Steps on controller
NEMA Class of Grids, if known. Otherwise, tell us what the motor is running, how often it starts, and how long it takes to come up to speed.
If speed control is needed, specify speed range.

To order DC crane control resistors, specify:

Motor hp
Volts
Torque
Amps.
Class
Steps

If class is not known, specify duty cycle, and lowering control.

ALL PRICES ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Have a salesperson contact me

Name
Title
Company
Address
E-mail
Phone
Product Requested

 
clear.gif (807 bytes)
Home ] Up ]
Send mail to info@jenkins.com with questions or comments about this web site.
Copyright 2001 Jenkins Electric Company